EIC Accelerator €2.2M awarded · Active in Morocco & Perth · Water Corporation extends pilots to three more Perth bores
Core business

High-recovery treatment for brackish groundwater.

SonixED™ is Hydrovolta’s core platform for brackish water in the 1–20 g/L TDS range — well and borehole water that is too salty to use and too valuable to abandon. It recovers more usable water, removes target ions selectively, and addresses the scaling dependencies that defeat conventional membrane systems in hard water and silica-laden sources.

Up to 95%recovery in a single pass
As little as 5%brine at 1–3 g/L
50–90%CIP reduction in validated contexts

Recovery depends on feed salinity →

Send your water analysis

TDS and hardness are enough to start. We respond within 3 business days.

We use your details and water data only to assess your project. See our privacy policy.

Recovery by feed salinity

Recovery depends on feed salinity.

One number cannot describe every source. What the plant recovers, and how much brine it leaves, follows the salinity of the feed.

Feed TDSRecoveryBrine
1–3 g/LUp to 95% (single pass)~5%
3–10 g/L~90%~10%
10–20 g/L75–85%15–25%

Figures depend on source chemistry and operating parameters. Send a water analysis and we state the expected envelope for your feed.

The challenge

The water is there. Scaling, contamination, rising salinity and brine disposal are the barriers.

Many brackish groundwater sources are technically and commercially viable — but not with conventional membrane systems. Silica fouling, variable salinity, high hardness, and brine disposal constraints compound in real operating conditions.

01

Brackish salinity

Target range 1–20 g/L TDS. Recovery targets and system configuration depend on source chemistry and operating parameters.

02

Scaling & silica fouling

Silica forms amorphous deposits that chemical cleaning cannot remove once established. SonixED™’s acoustic cavitation prevents nucleation before it occurs.

03

Ion-specific contamination

Nitrate, sodium, fluoride, and chloride require targeted removal. SonixED™’s selective membrane removes target ions while retaining Ca²¹ and Mg²¹.

04

Brine disposal constraints

SonixED™ leaves as little as 5% brine at 1–3 g/L — significantly less than conventional membrane treatment, reducing disposal burden and liability.

Hydrovolta engineers working on SonixED groundwater treatment system
How SonixED™ solves it

Electrodialysis reversal. Ultrasound anti-scaling. Selective membranes.

Three integrated mechanisms each addressing a specific failure mode of conventional treatment. Together they deliver a combination of recovery rate, scaling resistance, and ion selectivity that is not achievable with standard RO configurations for difficult brackish sources.

  • EDR: stable output under variable TDS. Polarity reversal cleans membranes without chemicals.
  • Ultrasound: prevents silica and hard-water scaling at source. 50–90% CIP reduction in validated contexts.
  • Selective membrane: removes NO₃¯, Na¹, Cl¯, F¯ while retaining Ca²¹, Mg²¹. No remineralisation required.
  • High recovery: up to 98% water recovery target. Where brine chemistry supports it, downstream valorization is evaluated.
Validated in the field

Active in Morocco and Perth.

Performance claims are tied to real operating data from active deployments, not laboratory projections.

Morocco active SonixED groundwater project
Morocco — active coastal brackish groundwater project
Perth agricultural and drinking water supply area
Perth — Water Corporation, drinking water & irrigation pilot
On-site commissioning and monitoring
On-site commissioning — Morocco deployment

SonixED™ performs best in specific conditions. Hydrovolta qualifies every project honestly — including when a different technology is a better fit.

Source characteristicSonixED™ fitNotes
TDS 1–20 g/LStrong fitCore operating range. Best economics vs RO at this TDS level.
High silica (>30 mg/l)Strong fitUltrasound prevents silica fouling that defeats conventional membranes.
High hardness (Ca + Mg >300 mg/l)Strong fitCaCO₃ and MgSO₄ scaling controlled by acoustic cavitation.
Selective nitrate removal requiredStrong fitValidated at Water Corporation Perth. EU limit 50 mg/l NO₃¯, already in force.
Inland site / no brine dischargeStrong fitAs little as 5% brine at 1–3 g/L minimises disposal burden. RO: roughly a third to a half of feed.
TDS <1 g/LBorderlineConventional softening or nano-filtration may be more cost-effective.
Not our use case: seawater (~35 g/L)Not primary use caseSWRO typically preferred. Hydrovolta focuses on the brine stream from existing SWRO.

Not sure where your source falls? Send your water analysis → Hydrovolta will assess fit without obligation.

See it operating

SonixED™ at a live groundwater deployment.

A walkthrough of active Hydrovolta equipment treating brackish groundwater in the field.

Assess your source

Send your groundwater analysis.

TDS, hardness, nitrate, silica, target flow, target use. We assess fit and design the configuration around your specific chemistry.

Institutional partners & backing

EIC
Flanders

Funder

Water Europe

Award

De Watergroep

Partner

Farys

Partner

GSTIC

Partner

Aquatech

Partner