Technology

Patented science. Deployed and operating.

SonixED™ integrates electrodialysis reversal, ultrasound-assisted scaling control, and a selective membrane coating into one automated platform. Developed through institutional research partnerships including VITO, CNR and others. Patent granted 2021. Active in Morocco and Perth.

SonixED membrane stack inside Hydrovolta treatment system
SonixED™

Three integrated mechanisms. One validated platform.

Each component of SonixED™ addresses a specific failure mode of conventional membrane treatment in the 1–20 g/L TDS brackish range. Together they deliver recovery and scaling resistance that individual technologies cannot achieve independently.

01

Electrodialysis Reversal (EDR)

Electric potential drives dissolved ions through ion-exchange membranes. Unlike reverse osmosis, water does not pass through the membrane — ions do. Periodic polarity reversal cleans membranes in-situ without chemical intervention, enabling stable performance across variable feed salinity.

  • Stable output under variable TDS feed conditions
  • Polarity reversal eliminates chemical CIP dependency
  • Lower hydraulic pressure than RO — reduced energy at low-to-medium TDS
02

Ultrasound Integration (Patent 2021)

Hydrovolta’s granted patent integrates ultrasound transducers directly at the membrane surface. Acoustic cavitation continuously disrupts scale nucleation and prevents silica fouling — addressing the primary failure mode of hard-water and silica-laden sources that defeats conventional membrane systems.

  • Acoustic cavitation prevents calcium, magnesium and silica scale
  • 50–90% reduction in CIP cycles in validated operating contexts
  • Extended membrane operational lifespan
03

Custom Membrane Coating

A proprietary membrane coating enables monovalent ion selectivity. The system removes nitrate, sodium, chloride, and fluoride while retaining beneficial calcium and magnesium. Output meets drinking water and agricultural standards without full demineralisation or downstream remineralisation.

  • Selective nitrate removal — validated at Water Corporation Perth (one utility site, three more bores in 2027)
  • Mineral-balanced output — no post-treatment cost
  • Configurable per application ion targets
Detailed SonixED process flow: brackish groundwater through pre-treatment, electrodialysis reversal and ultrasound, to clean water output with a brine valorization pathway
Hydrovolta engineer monitoring SonixED system performance at testing facility
Brine valorization

Chemical recovery where the concentrate chemistry supports it.

Where SonixED™ desalination produces residual brine with suitable ion composition, Hydrovolta evaluates and pilots chemical recovery using electromembrane separation and complementary technologies. The specific process configuration is determined by brine chemistry analysis and pilot assessment.

  • Brine composition assessed before any valorization pilot is recommended
  • Target product streams: HCl, NaOH, Mg(OH)₂, Ca(OH)₂ depending on chemistry
  • Configuration not fixed — designed per brine type and project objectives
  • Active alongside SonixED™ desalination in the Morocco integrated deployment
Performance reference

Qualified claims tied to validated operating data.

Every metric published by Hydrovolta is qualified by feedwater chemistry, operating conditions, and the context in which it was validated. No unqualified performance ranges are published.

Feed TDSRecoveryBrine
1–3 g/LUp to 95% (single pass)~5%
3–10 g/L~90%~10%
10–20 g/L75–85%15–25%
ParameterQualified public claimContext
Water recoveryUp to 95% recovery in a single pass on brackish groundwaterSubject to source chemistry and operating parameters
Residual brineAs little as 5% brine at 1–3 g/LSubject to feedwater TDS and recovery target
CIP reduction50–90% reduction in validated contextsHardness, silica, and scaling profile dependent
Ion selectivityMonovalent removal configured per applicationPerth: one utility site, three more bores in 2027
Valorization productsSubject to brine composition and pilot resultsDetermined per project chemistry assessment
Head-to-head comparison

Chemical plant, Germany — industrial cooling water, 90-day pilot (Feb–May 2023).

SonixED™ against reverse osmosis and standard EDR on the same feed water.

ParameterSonixED™Reverse OsmosisStandard EDR
Water recovery90–98%50–75%70–85%
Energy consumption0.19–0.7 kWh/m³2.0–4.0 kWh/m³1.0–2.0 kWh/m³
Chemical dosingMinimal — no anti-scalantRequiredAnti-scalants needed
Operating pressure0.5–2.5 bar25–35 bar1–2 bar
CIP cleaning frequency0.6×/month1×/month1×/month
Annual discharge reduction43,680 m³/yr26,880 m³/yr34,176 m³/yr
Total treatment cost$0.30–0.40/m³$0.60–1.00/m³$0.40–0.80/m³

Feed 4.5 g/L TDS, silica 85 mg/l. Cooling-water case; groundwater results depend on feed salinity (see table above).

Where these figures come from

Every figure in the table above comes from a single completed pilot: cooling tower blowdown at a chemical industry facility in Germany, Feb–May 2023, run as a 90-day head-to-head against reverse osmosis and standard EDR on the same feed water. They are not modelled, and they are not a composite of several sites.

Test conditions: TDS 4,500 ppm, silica 85 mg/l, high hardness.

Results on a different feed water will differ. We publish the conditions so the numbers can be checked against your own source.

Download the full case study →

See it in the field

SonixED™ — operating at a real deployment site.

George Brik walks through how SonixED™ operates on-site, from the containerised SalinBloc™ unit to the treatment stack inside.

Assessment

Send your water data. We assess the fit.

TDS, hardness, nitrate, silica, target flow. Our engineering team will assess whether SonixED™ is the right answer for your application.